Beacon Series™, Models BE-800-X (Subject to change without notice.)
CABINET-STYLE, WAIST-HIGH OPTICAL TURNSTILES
TURNSTILE SPECIFICATION: SECTION 10450
1.00 PART I GENERAL
1.01 Drawings and general provisions as specified apply to this section.
1.02 Product Data - integrator's general description for each item and
related components. For specific information, see catalog.
1.03 Shop drawings submitted upon request.
1.04 The www.TURNSTILES.us, Inc. Optical Turnstiles will utilize the building
access control systems to grant or deny access.
1.05 High-speed/nonrestrictive pedestrian passageways. Passageways are truly
bi-directional at all times.
2.00 PART II PRODUCTS
2.01 Turnstile models as provided by www.TURNSTILES.us, Inc., Conifer, Colorado
2.02 BEACON™ SERIES
202.1 Bollard construction: 304 Stainless steel. No. 4 brushed satin finish. Dimensions: 27-1/4" long x 37" high x
8-7/8" wide.
202.2 Top surface: 304 Stainless steel. No. 4 satin finish.
202.3 Optical sensors provide for passage for up to 30 people per minute. Throughput is
dependent on type of card reader technology and response time of the access system.
202.4 Visual and audible annunciation is provided at each passageway to provide
status of passageway, indication of valid card read, or alarm condition.
202.5 Horizontal Graphic Arrays/HGA's/solid state.
202.6 Optical sensors are provided to prevent individuals from obtaining unauthorized
access by crawling through the lane.
202.7 Distinctive tones for valid card and alarm condition. Adjustable volume control
with an 82 db maximum. Buzzer sounds upon alarm condition.
202.8 All components are designed specifically by www.TURNSTILES.us, Inc. for optical
turnstile high security access control products, and made in the USA.
202.9 All components including the HGA's are solid state in design and are virtually
maintenance free.
202.10 Power requirements: Power supply input 100/120/220/230/240 VAC 50/60HZ Output - 24 VDC @
2 amps. per passageway.
2.03 OPTIONS
203.1 Optional console device can remotely monitor and control lane use.
203.2 Alarm outputs: N/C, N/O relay rated at 5 amp @24 VDC/auxiliary alarm output contacts provided
for interface to building access control, fire/life safety, security, CCTV and monitoring systems.
3.0 PART III EXECUTION
3.01 Purchaser to install units in accordance with integrator's shop drawings
and installation manual.
3.02 Warranty: Units are warranted against defects in materials and workmanship
for a period of two years from date of delivery. See Warranty information
for specific details.
|